INSTALLING YOUR ICE MACHINE
Select Location
The proper location will ensure peak performance of your
appliance. We recommend a location where the unit will
be out of direct sunlight and away from heat sources. To
assure your product performs to specifications the recom-
mended installation location temperature range is from 55
to 80°F (13 to 27°C) for indoor built in units, 55 to 90°F
(13 to 32°C) for indoor freestanding units.
Outdoor Installation
Only the 3OiMT model is suitable for outdoor installations.
A ground fault circuit interrupter electrical receptacle is to
be used to supply electrical power to the refrigerator for
outdoor applications. Contact an electrician if you need
to install one to supply electrical power to your outdoor
wine cellar. Do not install in an environment where the unit
will be exposed to direct sun exposure as this may result in
unsatisfactory performance.
Cabinet Clearance
Ventilation is required from the bottom front section of the
unit. Keep this area open and clear of any obstructions.
Adjacent cabinets and counter top can be installed around
the unit as long as the grille and door access remain unob-
structed.
Figure 2
Do not splash or spray water from a hose on the ice •
machine. Doing so may cause an electrical shock,
which may result in severe injury or death.
This unit should not, under any circumstances, be •
ungrounded.
Grounding Method
This product is factory equipped with a power supply cord
that has a three-pronged, grounded plug. It must be
plugged into a mating grounding type receptacle in accor-
dance with the National Electrical Code and applicable lo-
cal codes and ordinances (see Figure 2). If the circuit does
not have a grounding type receptacle, it is the responsibility
and obligation of the customer to exchange the existing
receptacle in accordance with the National Electrical Code
and applicable local codes and ordinances. The third
ground prong should not, under any circumstances, be cut
or removed.
Electrical Connection
115 volts, 3 amps running max. 15 amp dedicated circuit
required. 3 prong grounded receptacle required.
Leveling Legs
Front Grille,
keep this
area open.
Figure 1
Do not use an extension cord
with this appliance.
Front Grille
Do not obstruct the front grille. The openings within the
front grille provide air to flow into and exit from the refrig-
erator condenser. For this reason it is important this area to
not be obstructed and be kept clean. Marvel does not rec-
ommend the use of custom made grilles as air flow may be
restricted because of inadequate openings. (See Figure 1).
Leveling Legs
Adjustable legs at the front and rear corners of the unit
should be set so the unit is firmly positioned on the floor
and level from side to side and front to back. Turn leveling
legs clockwise to raise unit, counterclockwise to lower it.
(See Figure 1).