USING YOUR MICROSENTRY™ REFRIGERATOR CONTROL
During inial startup, or anyme power is interrupted, there will
be an approximate 5 minute delay before the refrigerator starts.
During this period the controller will be assessing the tempera-
ture in the refrigerator and the display will appear errac, this is
normal. The desired temperature set point can be programmed
during this start up period.

The refrigerator will begin start up when inially plugged in or
when power resumes aer a power outage. At this me the re-
frigerator will take approximately 5 minutes to begin running as
noted above. If the refrigerator has been turned o during use,
“OFF” will appear on the display. To start the refrigerator from
the “OFF” posion press and hold the ON/OFF buon for three
seconds.
Set temperature
To set temperature set point, press and connue to hold “SET”
buon. Aer one second, set point will be displayed. While
holding “SET” buon use the “WARMER” or “COLDER” buon to
desired set point.
NOTE: Momentarily pressing & releasing “SET” buon will access
informaon menu of control. Refer to appendix A for informaon
on this feature.

The available temperature range of the refrigerator is 1° to 7° C.
It may take up to 24 hours for your refrigerator to reach desired
temperature. This will depend on amount of contents loaded
and number of openings and closings of the door.
For best results allow refrigerator to “pull down” to desired set
point before loading. Once contents are loaded, allow at least
48 hours for temperature to stabilize before making any adjust-
ments to the set point.
Alarms
Your MicroSentry™ refrigerator control will monitor refrigerator
funcon and alert you with a series of audible and visual alarms.
Door Ajar Alarm: If the door has been le
open for over ve (5) minutes, the alarm
will sound in one (1) second intervals. The
display panel will ash “do” and the LED light will be a steady
amber color. This will stop as soon as the door is closed.
High and Low Temperature Alarm: If your
unit reaches an unacceptable temperature
outside of your set point, the alarm will
sound in one (1) second intervals. The
display panel will ash either “hi” or “Lo”
depending upon the condion and the LED light will be a steady
amber color. “hi” indicates that the temperature is 5.5°C above
the set point and “Lo” indicates that the temperature is 5.5°C
below the set point. The alarm will remain acve unl the condi-
on is corrected.
NOTE: During inial appliance start-up, the high temperature
alarm may sound unl the interior temperature reaches set
point.
NOTE
Figure 8
NOTE
7
Set
Colder Warmer
ON/OFF
Press and Hold Press and Hold
Alarm
F
C
Close up of control
Control
Door Switch
Page view 6